Lead Glass

ZF6

Lead Glass

Products

Shanghai Je-see Technology

  Application Scenarios

ZF2,ZF3,ZF6,ZF7
ISO CE certified X‑ray lead glass, high‑performance radiation shielding glass for hospital CT and radiography rooms.
Feature
  • Meets ISO and CE certification standards, reliable quality for medical application.

  •  Excellent X‑ray radiation shielding performance, effectively blocks harmful rays.

  • Clear visual perspective, convenient for doctors to observe operating conditions.

  •  Customizable available size, fits various observation window installation demands.

  • Stable physical property, long service life for hospital daily clinical environment.

Technical Data

Serial No.Lead Glass Size(mm)Thickness(mm)Lead Equivalent(mmPb)
12000*120018-204
22000*100018-204
32000*100014-153
41800*100018-204
51800*100014-153
61500*100018-204
71500*90019-204
81500*90017-183.6
91500*90014-153
101200*100019-204
111200*100014-153
121200*90019-204
131200*90014-153
141200*80023-245
151200*80019-204
161200*80016-173.5
171200*80014-153
181200*8009-102
191000*80019-204
201000*80014-153
21900*60018-204
22900*60014-153
23800*60014-154
24800*6009-103
25600*40014-153
26600*4009-102
27400*30014-153
28400*3009-102
29356*35681.6

H7b322b69b2a645c2a4985e76d5aeeca0O

Product Instruction

Operation Manual of Medical X-ray Protective Glass

I.[Performance]

The  lead  equivalent  of the  protective  glass:0.25mmPb,0.35mmPb,0.5mmPb and so on

II.[Purpose]

The protective glass is mainly used for for the protection  of human  body during radiological diagnosis.

Ⅲ.[Application]

It is suitable for the X-ray protection.

IV.[Directions for Use]

Before operation,the operator should check whether the inner and outer surface packing of the protective glass is firm or not,whether the connection of accessories  is firm,check  whether  the  lead equivalent on the label is in line with the equivalent required by the operator.After the examination, start  the  operation.

V.[Attention]

1.when the surface is dirty,should first use a low concentration of cleaning solution or a small   amount of washing powder with a soft brush to scrub,and then clean with clean water,and then directly put it in the ventilated place to dry.

2.The protective products should be inspected regularly.The inspection method is to touch the cloth

with hands or remove the cloth surface for visual observation.If there is crack or damage,the products cannot be used and must be scrapped and replaced.

VI.[Storage   Conditions&Method]

It should be placed in a well-ventilated room away from direct sunlight and heat source.It is strictly prohibited to contact with acid,alkali and other chemicals.

VII.[useful life]

4 years.

VIII.[X-ray Tube Voltage]

100kV