Application Scenarios
LR01-XD60-1.2/5.5-40
It is specially designed for mammography soft tissue radiography systems.
Feature
- Dual-foucs structure enables both high-precision fine imaging and high-power radiography.
- High heat capacity rotating anode supports continuous shooting with efficient heat dissipation.
- Natural air cooling design, compact size, easy to install for portable DR equipment.
- Built-in thermal protection and lead shiedling ensure safe and stable long-term operation.
- Compatible with 50/60Hz power supply, widely matched with mainstream X-ray generators.
Technical Data
| IEC Classification | Class I Type B | ||
| Main Technical Indicators | |||
| Electrical Parameter | Circuit | Power Source (Neutral grounding) | Constant voltage type high voltage generator |
| Nominal X-ray Tube Voltage | Working voltage | 22~40 kV | |
| Nominal Focal Spot Value | Large Focus | .0.3 mm | |
| Small Focus | 0.1 mm | ||
Nominal Anode Input Power (.1s) | Large Focus, 50HZ | 5.5 KW | |
| Small Focus | 1.2 KW | ||
| Motor Rating | ||||
| Duty | Duty | Running | ||
| Power source (Hz) | 50/60 | 50/60 | ||
| Voltage (V) | 160 |
| ||
| Current (A) | 3.5~5 |
| ||
| Min. Speed up (s) | 1~1.2 | --- | ||
| Capacitor (μF) | 43/30 | 43/30 | ||
| Anode Speed | ||
| 50 HZ | 2800 rpm | |
| 60 HZ | 3200 rpm | |
| Stator impedance | ||
| Common Main Winding | 20.0Ω | |
| common-auxiliary Winding | 50.0Ω | |
Resistance between Housing and Low Voltage Terminals | 2MΩMin | |
Normal operating range of the housing temperature | 16~75 ℃ | |
| Physical Parameter | |
| Dimensions | See dimensional outline |
| Overall Length | 364.5 mm |
| Maximum Diameter | 138mm |
| Target | |
| Angle | 12° |
| Diameter | 64mm |
| Construction | Molybdenum Target |
| Total Filtration (Aluminum Equivalent) | |
| Inherent Filtration | 1.0mmBe |
| Leakage Technique Factor | 40 kV、2.0 mA |
| X-ray Coverage | 276mm * 276mm at SID 650mm |
| Weight | About 9.5 Kg |
| High Voltage terminal | ALDEN, P500 |
| Cooling Method | Natural |
| Absolute Maximum and Minimum Ratings (At any time, these values must not be exceeded.) | |
| Maximum Tube Voltage | 40 kV |
| Minimum Tube Voltage | 22 kV |
| Filament Current | |
| Small Focus | 4.5A |
| Large Focus | 7.1A |
| Filament Voltage | |
| Small Focus | 3.5±1V |
| Large Focus | 12V |
| Filament Frequency Limits | .0–25 kHz |
| Thermal Characteristics | |
| Anode Heat Storage | 150kJ (200 kHU) |
| Maximum Anode Heat Dissipation | 300W (425 kHU) |
| X-ray Tube Assembly Heat Content | 750kJ (500kHU) |
| Normal Continuous Input Power | |
| Without Air-circulator | 72W (6 kHU / min) |